Software Ingenuity for Smarter Hotels
Rest assured — every room is under control. NightGuard® protects overnight comfort. NightWatch® monitors the property. Alarms catch problems before guests notice —
all from one screen, on any device, anywhere.

When a VIP reservation is flagged, InnGenius Opal overrides standard energy setback policies for that room. The guest gets uninterrupted comfort — full climate control, no occupancy-based setbacks, no surprises at 2 a.m.
Every VIP action is recorded with a full audit trail: who set it, when, for how long. Management can review VIP usage across the property at any time.
Front desk managers, guest services directors, and operations teams. VIP Mode is typically applied for loyalty-tier guests, suite bookings, and special events where comfort is non-negotiable.
The difference between a five-star review and a complaint often comes down to one warm night in an otherwise perfect stay. VIP Mode eliminates that risk entirely.
NightGuard monitors and reacts in real time to occupancy changes during turn-down times and determines the occupancy state with precision accuracy. Our PIR motion sensors combined with our patented occupancy logic ensures no cold or hot guestroom complaints at 2 a.m.
NightGuard will always ensure a guest experiences their choice climate for a comfortable night's sleep.
In hotels with suites or multi-room configurations, standard EMS systems see the bedroom(s) as “unoccupied” overnight because their mediocre motion sensors and poor occupancy logic cannot accurately detect occupancy. This will inevitably trigger a guest complaint at 2am and a poor guest review.
NightWatch is your engineering team’s live view of the entire property during turn-down time. Every room, every thermostat, every open door — visible on one screen. When something goes wrong, NightWatch catches it in seconds and can alert security to take action to preserve guest safety.
Alarm states include proper escalation policies and a full acknowledgement workflow. When an engineer or team member handles an alarm, it’s recorded. When they don’t, it escalates. Every action is traceable.
Real-time room status, occupancy state, temperature, humidity, HVAC mode, door state, and alarm conditions — all updating continuously. Filter by floor, building, status, or alert type.
Prove your position when a guest complains about any HVAC or door issue —
because the data is always there.
Thermostats not communicating with the network.
Rooms outside comfort thresholds.
Active and historical alarm events.
HVAC compressor and fan runtime by room.
Estimated energy reduction across the property.
Highest energy-consuming rooms identified.
Overnight alarm and acknowledgement log.
Thermostat battery health across property.
Rooms in unoccupied state with active HVAC.
Active and historical VIP mode usage.
Rooms with long-term setback overrides.
Units that have been manually disabled.
Low Battery Notice — Thermostat batteries report their own state via status byte monitoring. Catch failing units before they silently drop from the mesh, creating blind spots in your coverage.
Opal Audio Alerts — Considered sound design for critical state changes. Web Audio API event tones notify your engineering console before a visual badge catches your eye. Different tones for different severity levels.
InnGenius Opal is a browser-based platform. Works on desktop, tablet, and mobile. Runs entirely on-premise with zero cloud dependency.
We do not use or interfere with the guest or property Wi-Fi. The EcoLodgix network communicates on its own dedicated RF mesh — completely independent of your network infrastructure.
InnGenius Opal runs entirely on your property network. No cloud dependency. No data leaves your building unless you choose it. Your IT team stays in full control.
View-only. Room temperatures, occupancy status. Ideal for front desk staff. Cannot modify any settings.
Modify room settings, view activity logs, access all 12 reports and the live dashboard. For engineering supervisors and duty managers.
All Manager access plus: write global settings, manage profiles, approve new user registrations, assign roles, and lock/unlock accounts.
Full system access. Reserved exclusively for EcoLodgix certified technicians. Includes all diagnostic and configuration capabilities.
The entire system runs on a single Windows server within your property network. No data leaves the building for core operations. No ongoing cloud subscription.
Two-layer entry barrier. Tokens are stored in JavaScript memory only — never in localStorage or cookies. Page refresh requires re-authentication.
Remote access via Cloudflare Tunnel — outbound-only connection, TLS 1.3 encryption, no port forwarding required. Your firewall stays closed.
Every settings change is logged with timestamp, username, and a before/after record. The system stores HVAC data only — no personally identifiable guest information is ever collected or stored.
Self-registration creates a pending account. No access is granted until an Admin or EcoTech user reviews, assigns a role, and activates the account.
A full IT Security & Access Reference document is available for your IT department. Contact us to request a copy.
Our team will walk through every feature on a live property. No slides, no simulations — real data, real rooms.